Esento Marine 8 Zone Conventional

Product code: ESEN-8MAR

8 zone marine approved fire alarm control panel available in grey and black. Esento Marine control panels are approved by MED, Lloyds Register & ABS for use in all seafaring vessels. The 8 zone offers a generous selection of programmable features including; muster alarm zone settings, 3 false alarm management modes, output delay settings, full networking capabilities up to 8 control panels and fully functional repeater panels.

Black panel product code: ESEN-8MAR-B

Up to 8 zonesNetworkingRepeatersMEDLloydsABSLPCB-810aUKCA FlagUKCAUKNICE

Where to buy
SKU: ESEN-8MAR Category: Brand: Esento Marine

Product Features

  • 8 zones
  • Network up to 8 control panels
  • Activate controls via key switch or code entry
  • Compatible with Apollo Orbis Marine detectors
  • Integral detector removal monitoring
  • Earth fault monitoring
  • 3 Amp switch mode power supply Nom 27V DC
  • 4 monitored sounder outputs
  • 2 Aux C/O relays (1 x Fire) (1 x Fault). voltage free
  • Class change I/P
  • Alert I/P
  • Fire & fault switched -ve outputs
  • Program delays to outputs
  • False alarm modes A, B & C
  • Muster alarm
  • Test mode, with or without sounders
  • Disable zones, sounder O/Ps, aux O/Ps & delays
  • Alarm load, 2.4A shared between all sounder outputs
  • All sounder circuits are fused @ 500mA with resettable fuses

Technical Specifications

Enclosure1.2mm Mild Steel IP30. Colour ref: MW334E Interpon powder coat
Cable EntryVia 20mm knockouts located in the top and rear of the cabinet
DimensionsBack box: 450mm W x 300mm H x 85mm D, Lid: 460mm W x 310mm H x 25mm D
Mains Supply3A internal switch mode power supply, Nom 27v DC
Battery Capacity2 x 7.0Ah 12v VRSLA
Detection Zones8 x conventional. EOL = 4K7R
Sounder Circuits4 x monitored, fused @500mA. EOL = 4K7R
NetworkingUp to 8 control panels, fault tolerant RS485 communication, requires TPCA05 network card
On Board Relays2 x programmable, 3A, 30v volt free changeover, additional relay provided on high spec zone card
Outputs2 x programmable, 40mA switch -ve, 2 additional outputs provided on high spec zone card
Switch InputsClass change & alert (pulsing)
Event Log40 event history
Intrinsically Safe ModeSelectable per zone
False Alarm ManagementType A, B & C dependency modes, approved by LPCB
Delay TimerOn board programmable delay timer 1-10 mins
Muster AlarmSelectable per zone